Balloon

Product description

Easy control of the heating / hot water pump

Euroster 11EK is an electronic, programmable controller, designed for cooperation with a central heating circulation pump or a pump filling the domestic hot water tank. It has an additional output to control a gas boiler or other heating device. The type of pump controlled is selected by software. Euroster 11EK is equipped with Anti Stop pump protection system, which prevents the seizing process of the unused pump impeller. After the end of the heating season, the system automatically starts the pump every two weeks for 30 seconds (for the system to work after the season, the controller should be left turned on).


     

Advantages

  • A device for controlling the central heating circulation pump or pump charging the domestic hot water tank in heating installations
  • Software mode of selecting the type of controlled pump
  • Automatic activation and deactivation of the circulation pump according to the set central heating temperature
  • Supervision over maintaining a constant water temperature for the domestic hot water tank
  • Cooperation with circulation pamphas for solid or gas boilers (without pump control system)
  • Temperature measurement using a sensor that measures the water temperature at the heating flow or in the water heater
  • In the central heating installation with a solid fuel boiler, the regulator will switch off the circulation pump after the boiler flame has extinguished.
  • Frost protection and pump operation test
  • Setting the temperature above the dew point prevents the boiler from sweating during heating the water in central heating
  • The Anti Stop System, which prevents the seizing process of the unused pump impeller, which starts the circulation pump (also outside the heating season) for approx. 30 seconds every 14 days

Downloads

EUROSTER 11EK – instrukcja obsługi.pdf
EUROSTER 11EK - руководство пользователя.pdf
Balloon
Balloon

Technical data

Euroster 11EK

Controlled device central heating or domestic hot water pump
Supply voltage 230 V 50 Hz
Maximum output load 3 A 230 V 50 Hz
Power consumption 1.6 watts
Temperature measurement range from -5 ° C to + 120 ° C
Temperature adjustment range from + 10 ° C to + 80 ° C
Accuracy of temperature control 1 ° C
Hysteresis range 2 ° C - 10 ° C
Visual signaling backlit LCD display
Working temperature from + 5 ° C to + 40 ° C
Storage temperature from 0 ° C to + 65 ° C
Level of security IP 40
Colour black
Mounting method wall, wall plugs
Driver mass with cables 0.54 kg
Standards, approvals, certificates compliance with EMC and LVD directives
Warranty 2 years
Dimensions: (width / height / depth) mm 150/90/52
Equipment Euroster 11EK controller, wall plugs, manual, mounting template, sensor band
Balloon
Balloon

Where to buy

You will find us easily
throughout the country

The Euroster Distributor Network is available throughout the country. Select a province from the list below and search for a Euroster distributor in your area. Do you want to become a Euroster distributor or are you our distributor and your company is not on the list? Contact us!

Customer service

tel. 65 571 15 16
Mon. - Fri: 7:00 a.m. - 4:00 p.m.

representatives

Please contact us
with our representatives
commercial

Service and support

Grzegorz Janusik
serwis@euroster.com.pl
tel. 65 571 20 12

Find a distributor

 
Program Inteligentny Rozwój Program Regionalny Samorząd woj. wielkopolskiego UE EFRR