Euroster 11K is a programmable controller dedicated to home heating installations with a water jacketed fireplace. It controls circulation pumps and an air damper and can work in one of three installation systems: central heating system supply through a plate heat exchanger, central heating system supply via a heat buffer and charging the hot utility water tank and central heating circuit supply via a plate heat exchanger. The controller is equipped with Anti Stop anti-stagnation pump protection system, which prevents seizing of the unused pump impeller in water-jacketed fireplaces. After the end of the heating season, the system automatically starts the pump every two weeks for 30 seconds (for the system to work after the season, the controller should be left turned on).
Controlled device | installing a fireplace with a water jacket |
Supply voltage | 230 V 50 Hz |
Maximum output load | 3 A (total) 230 V 50 Hz |
Power consumption | 4.3 W |
Controller outputs - voltage relay | pumps, throttle |
Controller outputs - voltage free | additional heat source |
Temperature measurement range | from 0 ° C to + 99 ° C |
Temperature adjustment range | from + 20 ° C to + 85 ° C |
Accuracy of temperature control | 1 ° C |
Accuracy of temperature indications | 1 ° C |
Hysteresis range | 1 ° C - 10 ° C |
Visual signaling | display and LEDs |
Working temperature | from + 5 ° C to + 40 ° C |
Storage temperature | from 0 ° C to 65 ° C |
Level of security | IP 30, protection class II |
Frame color | white |
Mounting method | 4M flush-mounted box |
Mass | 281 g |
Standards, approvals, certificates | compliance with EMC and LVD directives |
Warranty | 2 years |
Dimensions: width / height / depth (Mm) | 145/84/59 |
Equipment | Euroster 11K controller, temperature sensors: fireplace and tank (heat exchanger), instructions, sensor bands, flush-mounted box |