Euroster 11EK

Euroster 11EK
Euroster 11EK
Controller of the central heating circulation pump or pump charging the domestic hot water tank equipped with an additional output to control a gas boiler or other heating device. Type of pump controlled by software selection.

Euroster 11EK is an electronic, programmable controller, designed for cooperation with a central heating circulation pump or a pump filling the domestic hot water tank. It has an additional output to control a gas boiler or other heating device. The type of pump controlled is selected by software. Euroster 11EK is equipped with Anti Stop pump protection system, which prevents the seizing process of the unused pump impeller. After the end of the heating season, the system automatically starts the pump every two weeks for 30 seconds (for the system to work after the season, the controller should be left turned on).

Benefits
  • A device for controlling the central heating circulation pump or pump charging the domestic hot water tank in heating installations
  • Software mode of selecting the type of controlled pump
  • Automatic activation and deactivation of the circulation pump according to the set central heating temperature
  • Supervision over maintaining a constant water temperature for the domestic hot water tank
  • Cooperation with circulation pamphas for solid or gas boilers (without pump control system)
  • Temperature measurement using a sensor that measures the water temperature at the heating flow or in the water heater
  • In the central heating installation with a solid fuel boiler, the regulator will switch off the circulation pump after the boiler flame has extinguished.
  • Frost protection and pump operation test
  • Setting the temperature above the dew point prevents the boiler from sweating during heating the water in central heating
  • The Anti Stop System, which prevents the seizing process of the unused pump impeller, which starts the circulation pump (also outside the heating season) for approx. 30 seconds every 14 days
Technical specification
Controlled device central heating or domestic hot water pump
Supply voltage 230 V 50 Hz
Maximum output load 3 A 230 V 50 Hz
Power consumption 1.6 watts
Temperature measurement range from -5 ° C to + 120 ° C
Temperature adjustment range from + 10 ° C to + 80 ° C
Accuracy of temperature control 1 ° C
Hysteresis range 2 ° C - 10 ° C
Visual signaling backlit LCD display
Working temperature from + 5 ° C to + 40 ° C
Storage temperature from 0 ° C to + 65 ° C
Level of security IP 40
Colour black
Mounting method wall, wall plugs
Driver mass with cables 0.54 kg
Standards, approvals, certificates compliance with EMC and LVD directives
Warranty 2 years
Dimensions: (width / height / depth) mm 150/90/52
Equipment Euroster 11EK controller, wall plugs, manual, mounting template, sensor band
cennik
Selected other products from this category
Any questions? Do you need help selecting devices?

Our specialists are at your disposal. We will help you choose the right devices and prepare an offer for you.

Ask for an offer!
tel. +48 65 571 15 16
Mon-Fri: 7:00 - 16:00

Wholesale
Go to the list of our regional representatives
Where to buy
Search for the nearest distributor of EUROSTER devices. You can also shop directly in our online store.